Sean Ford 337373f8f0 fix(services): resolve and record a real pid when adopting a service (#8218)
ServiceSupervisor.start(), when probeBeforeSpawn detects an already-healthy
instance on the target port, "adopts" it (marks the service running without
spawning a duplicate that would die with EADDRINUSE). This adopt path calls
setToolStatus(tool, "running") with no pid argument at all, so this.pid stays
at its constructor default of null for the rest of that supervisor's life --
only the spawn path (a genuinely new child process) ever sets a real pid.

In production this "adopt" path is common, not an edge case: any embedded
sidecar service (cliproxy, 9router, bifrost, mux) whose child process
survives a `systemctl --user restart omniroute.service` gets adopted by the
new supervisor instance on the next start(), and its pid is lost from that
point on -- even though the service is genuinely healthy and running. The
observed symptom: a service shows state "running" but pid null, and
something downstream that keys liveness tracking off pid eventually treats
it as untrustworthy/stale despite nothing actually being wrong.

Fix: resolve the real pid of the process holding the port (via `lsof -ti
:<port>`, best-effort -- a lookup failure leaves pid null rather than
blocking adoption) and record it the same way the spawn path does.

An existing test asserted pid === null on adopt. That was accurate for the
old behavior but reflected a missing resolution, not a deliberate "adopted
services never get a pid" design choice -- updated its assertion to match
the corrected behavior and added a dedicated regression test proving the
resolved pid matches the real process actually bound to the port.