Diego Rodrigues de Sa e Souza 8587665669 fix(routing): fail over when Auggie's quota-exhausted text exits clean (#12949) (#13751)
Root cause: when a user's Augment/Auggie quota is exhausted, the local
`auggie` CLI prints its "You have run out of usage for ..." warning to
stdout and exits with code 0. AuggieExecutor treated any clean exit as
a successful completion and wrapped that text as a normal 200 assistant
reply, so combo/fallback routing never saw a failure and kept sending
requests to the same exhausted connection.

Fix: detect the CLI's known quota-exhausted phrasing before wrapping
stdout as a completion. Non-streaming returns a 429 in-band error body
(mirroring blackbox-web.ts's precedent for HTTP-200 in-band errors);
streaming buffers the first ~2KB of stdout, and on a match emits the
existing {error:...} SSE envelope (reusing the #7880 combo quality-gate
detection) instead of forwarding the text as a delta.

Regression test: tests/unit/issue-12949-auggie-quota-exhausted-200.test.ts